| Solicitation Number:2025-001041Trade Agreement:Implementing Rules and RegulationsProcurement Mode:Negotiated Procurement – Two Failed Biddings (Sec. 53.1)Classification:GoodsCategory:Medical and Dental EquipmentApproved Budget for the Contract:PHP 553,000.00 Delivery Period:15 Day/sClient Agency:Contact Person:JOSEPH M. ERECRE PhilGEPS Alternate In-charge New Capitol Complex, Tagbilaran City Bohol Philippines 6300 63-038-4110138 Ext.4212 63-38-09566438524 ppmu@bohol.gov.ph | Status | Active |
| Associated Components | 1 | |
| Bid Supplements | 2 | |
| Document Request List | 8 | |
| Date Published | 01/10/2025 | |
| Last Updated / Time | 14/05/2026 11:27 AM | |
| Closing Date / Time | 19/05/2026 17:00 PM | |
| Description ANNUAL PROCUREMENT PLAN (QUARTERLY) City of Tagbilaran FOR THE YEAR 2025 – Quarter : 2 MEDICAL AND DENTAL DEVICES AND EQUIPMENT Province, City or Municipality: Provincial Government of Bohol Total Cost Unit Qty Particulars Item No: Date Submitted : Constingency Regular All (Consolidated) Department / Office : 553,000.00 Total ALTERNATIVE MODE NEGOTIATED PROCUREMENT TWO-FAILED BIDDINGS Mode of Procurement: 553,000.00 Planned Amount 2025-001041 Plan Control No. PROVINCIAL GOVERNMENT OF BOHOL 2025-001041 General Diagnostics Devices & Equipment Lot No. 1 Unit 1 Newborn Screening Hearing Machine – testing of the newborn baby;s ability to hear. newborn screening for hearing is done with automated brainstem response tests or less often, with what are called oto-acoustic emission or conventional auditory brainstem response tests, DOH approved with LED monitor 47cm/19 monitor CPU, keyboard with mouse and AVR Vital Sign Monitor – Features: 8.4” color TFT LCD Screen (touch screen is an optional) Portable, lighter weight and sturdy design MEWS(Modified Early Warning Score) Calculations: Hemodynamics/Dose Calculation Rechargeable Li-ion Battery (up to 15 hours uninterruptible work) Spot-check and continuous monitoring mode Selectable for Adult, pediatric and neonatal patients Wire/WIFI/3G/4G CMS, Support HL7 protocol to HIS Barcode scanner, infrared ear thermometer support Night mode selectable, helps to reduce light stimulation and noise Graphical and tabular trend review(120 hours) 48 hours full disclosure wave review for each patient Display 8.4” color TFT LCD Screen,relosution:600×800 ECG Lead type 3-lead:l, II, Ill S· lead:l, II, lll,aVR, a VI., aVF, V ECG waveform:1 channel,7 channels Display sensitivity: 2.5mm;mv (x0.25), 5mm;mv (x0.5), 10mm;mv (x1.0), 20mm;mv {x2.0) Wave sweep speed: 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s Bandwidth Diagnostic mode: 0.05Hz-100Hz Monitor mode: 0.5Hz-40Hz Surgery mode: 1Hz-20Hz Strong filter mode: 5Hz-20Hz ANNUAL PROCUREMENT PLAN (QUARTERLY) City of Tagbilaran FOR THE YEAR 2025 – Quarter : 2 MEDICAL AND DENTAL DEVICES AND EQUIPMENT Province, City or Municipality: Provincial Government of Bohol Total Cost Unit Qty Particulars Item No: Date Submitted : Constingency Regular All (Consolidated) Department / Office : 553,000.00 Total ALTERNATIVE MODE NEGOTIATED PROCUREMENT TWO-FAILED BIDDINGS Mode of Procurement: 553,000.00 Planned Amount 2025-001041 Plan Control No. PROVINCIAL GOVERNMENT OF BOHOL 2025-001041 General Diagnostics Devices & Equipment Lot No. 1 Unit 1 Newborn Screening Hearing Machine – testing of the newborn baby;s ability to hear. newborn screening for hearing is done with automated brainstem response tests or less often, with what are called oto-acoustic emission or conventional auditory brainstem response tests, DOH approved with LED monitor 47cm/19 monitor CPU, keyboard with mouse and AVR 1 370,000.00 Lot/ SubCategory Total : Patient Monitoring System Devices & Equipment Lot No. 2 PGBh-US Procurement unit 1 CMRR>100dB Notch: 50/60Hz notch filter can be set to on or off Differential input impedance> 5M? Electrode polarization voltage range: ±400mV HR range:15-350 bpm Baseline recovery time<3s after defibrillation {in monitor and surgery mode) Calibration signal:1mV (peak – peak), accuracy ±3% RESP Measurement method : Thoracic electrical bioimpedance Measuring lead: Lead I, II Wave gain: x0.25, xO.5, x 1, x2 Respiratory impedance range: 0.5 -5? 0-150 bpm Baseline impedance: 500-4000? Gain: 10 grades Scan speed: 6.25mm/s, 12.5 mm/s, 25mm/s TEMP Measurement method: Thermistor Measuring range: 5~5O degree celcius (41-122degree farenheit) Resolution: 0.1degree celcius Measurement accuracy: ±0.1degree celcius Recorder (optional) Built-in, Thermal dot array Horizontal resolution :16 dots/mm (25 mm/s paper speed) Vertical resolution:8 dots/mm Paper speed:25 mm/s, 50 mm/s Number of waveform channels:3 NIBP Measurement method : Automatic oscillometric method Operating mode: Manual, automatic, continuous Measurement unit: mmHg/kPa selectable Typical measurement time: 20-35s Measurement type: Systolic, Diastolic, Mean Measurement range {mmHg) Range of Systolic pressure: Adult 40-270 Pediatric 40-230 Neonatal 40-135 Range of Diastolic pressure: Adult 10-215 Pediatric 10-150 Neonatal 10-100 Range of Mean pressure: Measurement accuracy Adult 20-235 Pediatric 20-165 Neonatal 20-110 Measurement accuracy Maximum average error: ±5mmHg Maximum standard deviation: 8mmHg Resolution: 1 mmHg lnterval:1 ,2,3,4,5, 10, 15,30,60,90, 120, 180,240,480minutes Overpressure protection: Software and hardware, double safety protection Cuff pressure range: 0-290mmHg SpO2 Measurement range : 0-100% Resolution: 1% Parameter monitoring: perfusion index(PI):0-20% optional pleth variability index(PVI) Accuracy: ±2% or ±2bpm Refreshing Rate: 1 s Pulse rate Range: 30~300 bpm Resolution: 1bpm Accuracy: ±2bpm(non motion) 1 PGBh-US Procurement ±5bpm (motion) Refreshing rate:1s Operating Environment Input power: AC 100-250V,50/60Hz Temperature: 5-40 degree celcius Humidity: <85% Patient Range: Adult, Pediatric, Neonate 183,000.00 Lot/ SubCategory Total : This is to certify that the above annual procurement plan is in accordance with the objectives of this office/agency Prepared by: PAULITO H. RABUYA Head, BAC Secretariat 2025-001041 Period of Delivery: 15 days | ||
| Remarks Extension of Advertisement | ||