Solicitation Number:2025-001157Trade Agreement:Implementing Rules and RegulationsProcurement Mode:Negotiated Procurement – Two Failed Biddings (Sec. 53.1)Classification:GoodsCategory:Laboratory Supplies and EquipmentApproved Budget for the Contract:PHP 400,000.00 Delivery Period:15 Day/sClient Agency:Contact Person:ALVIN ANTOPINA
PhilGEPS In-charge
New Capitol Complex,
Tagbilaran City
Bohol
Philippines 6300
63-038-4110138 Ext.4212
63-38-09566438524
ppmu@bohol.gov.ph
StatusActive
Associated Components1
Bid Supplements0
Document Request List1
Date Published03/12/2025
Last Updated / Time03/12/2025 00:00 AM
Closing Date / Time10/12/2025 10:30 AM
Description ANNUAL PROCUREMENT PLAN (QUARTERLY)
City of Tagbilaran
FOR THE YEAR 2025 – Quarter : 3
LABORATORY EQUIPMENT, PARTS AND MAINTENANCE SERVICES
Province, City or Municipality: Provincial Government of Bohol
Total Cost Unit Qty Particulars Item No:
Date Submitted : Constingency Regular All (Consolidated) Department / Office :
400,000.00 Total
ALTERNATIVE MODE
NEGOTIATED
PROCUREMENT
TWO-FAILED
BIDDINGS
Mode of Procurement:
400,000.00 Planned Amount 2025-001157 Plan Control No.
PROVINCIAL GOVERNMENT OF BOHOL
2025-001157
Laboratory Diagnostics Equipment Lot No.
1
Unit 1
Multiplex Fluorescent Analyzer – The instrument
consists of a main unit, hair lysis buffer, detection
reagent kits, and a power adapter.
The instrument should have CE IVDR certificate.
The instrument supports real-time data storage,
viewing, and printing, with a storage capacity of no less
than 10,000 records.
The instrument has a self-check function that
automatically detects all key components during
startup.
s. Power supply voltage: ~100V-240V Frequency: 50Hz
/ 60Hz Main unit dimensions: 220mm (W) x 278mm (D)
x 171mm (H) The Total weight should be no more than
3KGS ,.
Operating wavelength range: 365nm.
Detection range: 0-65,535.
Startup warm-up time: 20 minutes
Power consumption: 60VA.
Operating temperature range: 10°C-35°C.
Relative humidity range: 10%-70%.
Atmospheric pressure range: 80.0kPa-106.0kPa.
Instant test mode: Supported.
Real-time fault diagnosis function: Can identify and
alert faults during self-check or operation.
Calibration function: Instrument can be calibrated by
reading a quality control card.
Standard curve import: Can import standard curves via
external interface. Interface types: USB: 2 ports ID card
slot: 1 Serial port: 1 Power supply port:
1. The instrument can read the QR code on the test
card and automatically match it to the sample type.
Cold start time is ?1 minute. Linearity: r > 0.990
Repeatability: CV ? 5%. Stability: ? +5%. Accuracy: +15
%
Linear detection 0-65,535 arbitrary fluorescence units
(AFU). Analytical Capacity: Compatible with single
channel test cassettes containing up to 6 discrete
sample wells; supports simultaneous analysis of up to
18 analytes per test. Sample types: hair. Data export:
Supports batch export; compatible with LIS/HIS.
Operating Platform: Android-based system architecture.
1
400,000.00 Lot/ SubCategory Total :
This is to certify that the above annual procurement plan is in accordance with the objectives of this
office/agency
Prepared by:
PAULITO H. RABUYA
Head, BAC Secretariat
Printed by : 2345 on 12/2/2025 8:20:30 AM
2025-001157
Period of Delivery: 15 days