| Solicitation Number:2025-001157Trade Agreement:Implementing Rules and RegulationsProcurement Mode:Negotiated Procurement – Two Failed Biddings (Sec. 53.1)Classification:GoodsCategory:Laboratory Supplies and EquipmentApproved Budget for the Contract:PHP 400,000.00 Delivery Period:15 Day/sClient Agency:Contact Person:ALVIN ANTOPINA PhilGEPS In-charge New Capitol Complex, Tagbilaran City Bohol Philippines 6300 63-038-4110138 Ext.4212 63-38-09566438524 ppmu@bohol.gov.ph | Status | Active |
| Associated Components | 1 | |
| Bid Supplements | 0 | |
| Document Request List | 1 | |
| Date Published | 03/12/2025 | |
| Last Updated / Time | 03/12/2025 00:00 AM | |
| Closing Date / Time | 10/12/2025 10:30 AM | |
| Description ANNUAL PROCUREMENT PLAN (QUARTERLY) City of Tagbilaran FOR THE YEAR 2025 – Quarter : 3 LABORATORY EQUIPMENT, PARTS AND MAINTENANCE SERVICES Province, City or Municipality: Provincial Government of Bohol Total Cost Unit Qty Particulars Item No: Date Submitted : Constingency Regular All (Consolidated) Department / Office : 400,000.00 Total ALTERNATIVE MODE NEGOTIATED PROCUREMENT TWO-FAILED BIDDINGS Mode of Procurement: 400,000.00 Planned Amount 2025-001157 Plan Control No. PROVINCIAL GOVERNMENT OF BOHOL 2025-001157 Laboratory Diagnostics Equipment Lot No. 1 Unit 1 Multiplex Fluorescent Analyzer – The instrument consists of a main unit, hair lysis buffer, detection reagent kits, and a power adapter. The instrument should have CE IVDR certificate. The instrument supports real-time data storage, viewing, and printing, with a storage capacity of no less than 10,000 records. The instrument has a self-check function that automatically detects all key components during startup. s. Power supply voltage: ~100V-240V Frequency: 50Hz / 60Hz Main unit dimensions: 220mm (W) x 278mm (D) x 171mm (H) The Total weight should be no more than 3KGS ,. Operating wavelength range: 365nm. Detection range: 0-65,535. Startup warm-up time: 20 minutes Power consumption: 60VA. Operating temperature range: 10°C-35°C. Relative humidity range: 10%-70%. Atmospheric pressure range: 80.0kPa-106.0kPa. Instant test mode: Supported. Real-time fault diagnosis function: Can identify and alert faults during self-check or operation. Calibration function: Instrument can be calibrated by reading a quality control card. Standard curve import: Can import standard curves via external interface. Interface types: USB: 2 ports ID card slot: 1 Serial port: 1 Power supply port: 1. The instrument can read the QR code on the test card and automatically match it to the sample type. Cold start time is ?1 minute. Linearity: r > 0.990 Repeatability: CV ? 5%. Stability: ? +5%. Accuracy: +15 % Linear detection 0-65,535 arbitrary fluorescence units (AFU). Analytical Capacity: Compatible with single channel test cassettes containing up to 6 discrete sample wells; supports simultaneous analysis of up to 18 analytes per test. Sample types: hair. Data export: Supports batch export; compatible with LIS/HIS. Operating Platform: Android-based system architecture. 1 400,000.00 Lot/ SubCategory Total : This is to certify that the above annual procurement plan is in accordance with the objectives of this office/agency Prepared by: PAULITO H. RABUYA Head, BAC Secretariat Printed by : 2345 on 12/2/2025 8:20:30 AM 2025-001157 Period of Delivery: 15 days | ||